Research on the imaging of concrete defect based on the pulse compression technique
Li Chang-Zheng1,2, Zhang Bi-Xing1, Shi Fang-Fang1, and Xie Fu-Li1
1. State Key Laboratory of Acoustic, Institute of Acoustics, Chinese Academy of Sciences, Beijing.
100190, China.
2. The Yellow River Institute of Hydraulic Research, Zhengzhou 450003, China.
Abstract:
When the synthetic aperture focusing technology (SAFT) is used for the detection of the concrete, the signal-to-noise ratio (SNR) and detection depth are not satisfactory. Therefore, the application of SAFT is usually limited. In this paper, we propose an improved SAFT technique for the detection of concrete based on the pulse compression technique used in the Radar domain. The proposed method first transmits a linear frequency modulation (LFM) signal, and then compresses the echo signal using the matched filtering method, after which a compressed signal with a narrower main lobe and higher SNR is obtained. With our improved SAFT, the compressed signals are manipulated in the imaging process and the image contrast is improved. Results show that the SNR is improved and the imaging resolution is guaranteed compared with the conventional short-pulse method. From theoretical and experimental results, we show that the proposed method can suppress noise and improve imaging contrast, and can also be used to detect multiple defects in concrete.
LI Chang-Zheng,ZHANG Bi-Xing,SHI Fang-Fang et al. Research on the imaging of concrete defect based on the pulse compression technique[J]. APPLIED GEOPHYSICS, 2013, 10(3): 337-348.
[1]
Chang, Y. F., Wang, C. Y., and Hsieh, C. H., 2001, Feasibility of detecting embedded cracks in concrete structures by reflection seismology: NDT&E International, 34(1), 39 - 48.
[2]
Chiao, R. Y., and Hao, X. H., 2005, Coded excitation for diagnostic ultrasound: a system developer’s perspective: Ultrasonics, IEEE Transactions on Ferroelectrics and Frequency Control, 52(2), 160 - 170.
[3]
Hayes, M. P., and Gough, P. T., 1992, Broad-band synthetic aperture sonar: IEEE Journal of Oceanic Engineering, 17(1), 80 - 94.
[4]
Lancée, C. T., Vissers, J. M., Mientki, S., Ligtvoet, C. M., and Bom, N., 1987, Influence of phase errors on beam-steered phased arrays: Ultrasonics, 25(3), 154 - 159.
[5]
Liang, M. T., and Su, P. J., 2001, Detection of the corrosion damage of rebar in concrete using impact-echo method: Cement and Concrete Research, 31(10), 1427 - 1436.
[6]
Li, Q. F., Shi, L. H., and Liang, D. K., 2008, Study on 2D imaging technique for concrete cross section based on SAFT: Acta Acoustic, 33(4), 370 - 377.
[7]
Litniewski, J., Nowicki, A., Klimonda, Z., and Lewandowski, M., 2007, Sound Fields for Coded Excitations in Water and Tissue: Experimental Approach: Ultrasound in Medicine & Biology, 33(4), 601 - 607.
[8]
Liu, P. L., Tsai, C. D., and Wu, T. T., 1996, Imaging of surface-breaking concrete cracks using transient elastic waves: NDT& E International, 29(5), 323 - 331.
[9]
Ludwig, R., and Roberti, D., 1989, A nondestructive ultrasonic imaging system for detection of flaws in metal blocks: IEEE Transactions on Instrumentation and Measurement, 38(1), 113 - 118.
[10]
Mamou, J., Ketterling, J. A., and Silverman, R. H., 2008, Chirp-coded excitation imaging with a high-frequency ultrasound annular array: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 55(2), 508 - 513.
[11]
Marti?n-Arguedas, C. J., Romero-Laorden, D., Marti?nez-Graullera, O., Pe?rez-Lo?pez, M., and Go?mez-Ullate, L., 2012, An ultrasonic imaging system based on a new SAFT approach and a GPU beamformer: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 59(7), 1402 - 1412.
[12]
Misaridis, T., and Jensen, J. A., 2005, Use of modulated excitation signals in medical ultrasound. Part II: basic concepts and expected benefits: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 52(2), 192 - 207.
[13]
O’Donnell, M., and Wang, Y., 2005, Coded excitation for synthetic aperture ultrasound imaging: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 52(2), 171 - 176.
[14]
Popovics, J. S., and Rose, J. L., 1994, A survey of developments in ultrasonic NDE of concrete: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 41(1), 140 - 143.
[15]
Qin, Z., Lu, M. H., Zheng, X. D., Yao, Y., Zhang, C., and Song, J. Y., 2009, The implementation of an improved NPML absorbing boundary condition in elastic wave modeling: Applied Geophysics, 6(2), 113 - 121.
[16]
Tong, J. H., Liao, S. T., and Lin, C. C., 2007, A new elastic-wave-based imaging method for scanning the defects inside the structure: IEEE Transactions on ltrasonics, Ferroelectrics and Frequency Control, 54(1), 128 - 137.
[17]
Wooh, S. C., and Shi, Y. J., 1998, Influence of phased array element size on beam steering behavior: Ultrasonics, 36(6), 737 - 749.
[18]
Wu, T. T., Fang, J. S., and Liu, P. L., 1995, Detection of the depth of a surface-breaking crack using transient elastic waves: J. Acoust. Soc. Am, 97(3), 1678 - 1686.
[19]
Yoshihiko, O., Hiroaki, S., Toshimasa, T., and Mitsuo, T., 1988, A new system for real-time synthetic aperture ultrasonic imaging: Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on, 35(6), 828 - 838.
[20]
Zhang, C. G., Zhang, B. X., Deng, F. Q., and Shi, F. F., 2008, Non-integer dimension ultrasonic phased array testing: Acta Acustica, 33(6), 555 - 561.